Abstract
ISO 16975-3:2017 specifies guidance on how to conduct fit testing of tight-fitting respiratory protective device (RPD) and on appropriate methods to be used. Fit testing is only one element of a complete RPD programme. The intention of fit testing is to evaluate the effectiveness of the seal between the wearer's face and the respiratory interface (RI). A complete RPD programme is defined in ISO/TS 16975‑1.
ISO 16975-3:2017 specifies requirements for conducting RPD fit testing and includes
- qualifications/competences of fit-test operators,
- specific fit-testing procedures,
- interpretation of fit-test results, and
- record keeping.
A fit test is not required for escape-only RPD.
General information
-
Status: PublishedPublication date: 2017-09Stage: International Standard to be revised [90.92]
-
Edition: 1Number of pages: 28
-
Technical Committee :ISO/TC 94/SC 15ICS :13.340.30