Reference number
ISO 2719:2016
International Standard
ISO 2719:2016
Determination of flash point — Pensky-Martens closed cup method
Edition 4
2016-06
Read sample
ISO 2719:2016
62263
Published (Edition 4, 2016)
This publication was last reviewed and confirmed in 2021. Therefore this version remains current.
This standard has 1 amendment.

ISO 2719:2016

ISO 2719:2016
62263
Language
Format
CHF 129
Convert Swiss francs (CHF) to your currency

Abstract

ISO 2719:2016 describes three procedures, A, B and C, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 °C to 370 °C.

CAUTION - For certain mixtures no flash point, as defined, is observed; instead a significant enlargement of the test flame (not halo effect) and a change in colour of the test flame from blue to yellowish-orange can occur. Continued heating can result in significant burning of vapours outside the test cup, and can be a potential fire hazard.

NOTE 1 Although, technically, kerosene with a flash point above 40 °C can be tested using this International Standard, it is standard practice to test kerosene according to ISO 13736.[5] Similarly, lubricating oils are normally tested according to ISO 2592[2].

Procedure A is applicable to distillate fuels (diesel, biodiesel blends, heating oil and turbine fuels), new and in-use lubricating oils, paints and varnishes, and other homogeneous liquids not included in the scope of Procedures B or C.

Procedure B is applicable to residual fuel oils, cutback residua, used lubricating oils, mixtures of liquids with solids, liquids that tend to form a surface film under test conditions or are of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of Procedure A.

Procedure C is applicable to fatty acid methyl esters (FAME) as specified in specifications such as EN 14214[11] or ASTM D6751[13].

ISO 2719:2016 is not applicable to water-borne paints and varnishes.

NOTE 2 Water-borne paints and varnishes can be tested using ISO 3679[3]. Liquids containing traces of highly volatile materials can be tested using ISO 1523[1] or ISO 3679.

General information

  •  : Published
     : 2016-06
    : International Standard to be revised [90.92]
  •  : 4
     : 22
  • ISO/TC 28
    75.080 
  • RSS updates

 Amendments

Amendments are issued when it is found that new material may need to be added to an existing standardization document. They may also include editorial or technical corrections to be applied to the existing document.

Amendment 1

Thermometers correction

Edition 2021

ISO 2719:2016/Amd 1:2021
79763
Language
Format
CHF 18
Convert Swiss francs (CHF) to your currency

Next version under development

Draft
International Standard
ISO/DIS 2719
Determination of flash point — Pensky-Martens closed cup method
Reference number
ISO/DIS 2719
Edition 1
Draft International Standard

ISO/DIS 2719

Determination of flash point — Pensky-Martens closed cup method

Amendment 1: Thermometers correction

ISO/DIS 2719

ISO/DIS 2719
89338
Language
Format
CHF 63
Convert Swiss francs (CHF) to your currency

Life cycle

Got a question?

Check out our Help and Support