This document specifies a molecular absorption spectrophotometric method for the determination of titanium content in nickel alloys.
The method is applicable to titanium contents between 0,3 % (mass fraction) and 5,0 % (mass fraction).
Molybdenum, if present in the alloy, can cause a high bias in the reported titanium value to the extent of 0,001 % Ti for every 1,0 % Mo.
NOTE 1 Evidence exists that extension of this method is possible for titanium contents down to 0,05 % (mass fraction).
NOTE 2 Modifications in the general method allow the determination of titanium in alloys containing tungsten and/or tantalum.
Informaciones generales
-
Estado: PublicadoFecha de publicación: 2020-11Etapa: Norma Internacional publicada [60.60]
-
Edición: 2Número de páginas: 8
-
Comité Técnico :ISO/TC 155ICS :77.120.40